How to calculate copper weight in a cable
The default density is 8.96 g/cm³, the pure copper value listed by NIST. Actual conductor density and manufactured geometry can differ. You can change the density input when your specification provides a different value.
Example: 3 × 2.5 mm² cable, 100 metres
3 × 2.5 × 100 × 8.96 ÷ 1,000 = 6.72 kg. At this density the theoretical copper weight per metre is 0.0672 kg. This is conductor mass, not the total cable shipping weight.
What is excluded?
Insulation, sheath, fillers, screens, armour, packaging, process losses and stranding lay-length allowances are excluded. Nominal conductor area is used as a geometric estimate; it is not a guarantee of the actual metal quantity in a manufactured cable.
Can I calculate unequal cores?
Calculate each group separately and add the results. For example, calculate three equal phase conductors as one group and a smaller protective conductor as another. Use only copper cores in this calculator.